EX-500 Series
Inductive Displacement Sensor |

|
Specifications
Best in Class Performance with the Specifications to Prove it
EX-500 Series Specifications
| Type |
Size |
M8 |
M8 |
M16 |
M22 |
| Model |
Sensor head |
EX-008 |
EX-008 |
EX-016 |
EX-022 |
| Controller |
EX-501 |
EX-502 |
EX-505 |
EX-510 |
| Measuring range |
0 to 1 mm 0.04" |
0 to 2 mm 0.08" |
0 to 5 mm 0.20" |
0 to 10 mm 0.39" |
Analog output |
Output voltage |
0 to 5 V (Output impedance: 100 Ω) |
| Output current |
4 to 20 mA (Applicable load: 0 to 350 Ω) |
| Resolution |
0.03% of F.S. (RESPONSE = 3, 4) |
| Linearity |
±0.3% of F.S. (RESPONSE = 2, 3, 4) |
Response time (Response mode) |
0.1 ms (RESPONSE = 1), 1 ms (RESPONSE = 2), 10 ms (RESPONSE = 3), 100 ms (RESPONSE = 4) |
| Disconnection alarm output (1) (N.C.) |
NPN: 100 mA max. (40 V), Residual voltage: 1 V max. |
| Functions |
Auto-zero function / Auto-span function, Response time selector function /
Preset metal characteristic memory function, Cable length selector function /
Interference suppression function |
Temperature fluctuation |
Sensor head |
0.03% of F.S./ºC |
| Controller |
0.04% of F.S./ºC (2) |
| Power supply voltage |
12 to 24 VDC ±10% |
| Current consumption |
220 mA max. |
| Enclosure rating |
Sensor head: IP-67 |
Ambient temperature |
Sensor head |
-20 to +105ºC(-4 to 221ºF), No condensation |
| Controller |
0to +50ºC(32 to 122ºF), No condensation |
| Relative humidity |
35 to 85%, No condensation |
| Weight |
Sensor head |
Approx. 50 g |
Approx. 63g |
Approx. 80g |
| Controller |
Approx. 360 g |
The above data was obtained using an aluminum target (A5052 t=1 mm 0.04" ). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these
materials.
1. NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter.
2. When the distance between the sensor head and the target is 50% of the measuring range and the operating temperature is 10 to +40ºC (32 to 104ºF) (EX-008) or 0 to
+50ºC (32 to 122ºF) (EX-016 and EX-022).
For Full Details