Products

General Catalog

Want to learn how to use our products? - go to Application Finder Page

Explore theLatest Measurement System? - go to Product Finder Page

Laser Displacement Sensors from KEYENCE

IG Series

Multi-Purpose CCD Laser Micrometer
Print Page
Select a Page Below:
BackNext
Specifications 1

IG Series Multi-Purpose CCD Laser Micrometer

Best in Class Performance with the Specifications to Back it Up.

Sensor heads
Model IG-010 IG-028
Appearance IG-010 IG-028
Operation principle CCD method
Light source Visible light semiconductor laser (Wavelength:660 nm)
FDA (CDRH)
Part 1040.10
Class 1 1.
IEC60825-1 Class 1
Mounting distance 0 to 1000 mm 39.37" 0 to 1500 mm 59.06"
Measurement range 10 mm 0.39" 28 mm 1.10"
Sampling cycle 980μs (When the number of times for averaging is set to [hsp]: 490μs)
Minimum detectable
object 2.
High sensitivity
mode
ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94")
Standard mode ø0.2 mm ø0.007"
(Setting distance: 40 mm 1.57" or less),
ø0.5 mm ø0.02"
(Setting distance: 500 mm 19.68")
ø0.2 mm ø0.007"
(Setting distance: 50mm 1.97" or less),
ø0.5 mm ø0.02"
(Setting distance: 500 mm 19.68")
Repeatability 3. 5 μm 0.20 Mil
(Setting distance: 100 mm 3.94")
10 μm 0.39 Mil
(Setting distance: 500 mm 19.68")
80 μm 3.15 Mil
(Setting distance: 1000 mm 39.37")
5 μm 0.20 Mil
(Setting distance: 100 mm 3.94")
10 μm 0.39 Mil
(Setting distance: 500 mm 19.68")
80 μm 3.15 Mil
(Setting distance: 1000 mm 39.37")
140 μm 5.51 Mil
(Setting distance: 1500 mm 59.06")
Linearity 4. ±0.28 % of F.S. (±28 μm ±1.10 Mil) ±0.1 % of F.S. (±28 μm ±1.10 Mil)
Temperature characteristics 5. ±0.03 % of F.S./ºC
(±3 μm ±0.12 Mil/ºC)
±0.01 % of F.S./ºC
(±3 μm ±0.12 Mil/ºC)
Operation indicator Transmitter Optical axis alignment indicator: Green LED Power indicator: Green LED
Receiver Optical axis alignment indicator: Green LED Position monitor:
Dual bar LED (Red, Green)
Environment resistance Enclosure rating IP67
Ambient
temperature
-10 to +45ºC 14 to 113Fº (No freezing)
Ambient humidity 35 to 85% RH (No condensation)
Ambient light 6. Incandescent lamp: 5000 lux Sunlight: 5000 lux
Vibration
resistance
10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours
Material Case Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part),
SUS304 (Metallic part)
Lens cover Glass
Cable PVC
Supplied item Transmitter x 1, Receiver x 1, Sensor head cables (2 m 0.08") x 2
Weight (including supplied items) Approx. 380 g Approx. 500 g
1. The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
2. When the measurement target object is measured at the center position of the setting distance.
When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm 0.003" or more can be detected (Setting distance: 500 mm 19.69").
3. When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds.
(When the analog output is used, the margin of error of analog output is added.)
4. When the setting distance is 100 mm 3.94” and light is shielded at 50 mm 1.96" position from the receiver. Margin of error to the ideal line.
5. When the setting distance is 100 mm 3.94” and light is shielded by half at 50 mm 1.96” position from the receiver.
6. Excluding when the average number of times is set to [hsp].
Display unit (amplifier)
Model IG-1000 IG-1050 IG-1500 IG-1550
Appearance IG-1000 IG-1050 IG-1500 IG-1550
Amplifier type DIN rail mount Panel mount
Main unit/Expansion unit Main unit Expansion unit Main unit Expansion unit
Analog output Yes No Yes No
Power supply voltage 10-30 VDC, Ripple (P-P): 10% included, Class 2
Power consumption
(including analog current output)
Normal 2700 mW or less
(at 30 V: 90 mA or less)
2880 mW or less
(at 30 V: 96 mA or less)
Power saving
function (HALF)
2300 mW (at 30 V: 77 mA or less)
Power saving
function (ALL)
2200 mW (at 30 V: 74 mA or less)
Digital display method Dual 7-seg display
Upper level: Red, 5 digits
Lower level: Green, 5 digits
Dual 7-seg display
Upper level: Red/Green, 2 colors, 5 digits
Lower level: Green, 5 digits
Display range -99.999 to +99.999, -99.99 to +99.99, -99.9 to +99.9, -99 to +99 (selectable)
Display resolution 1 μm 0.04 Mil, 10 μm 0.39Mil, 100 μm 3.94 Mil, 1000 μm 39.37 Mil(selectable )
Output Judgement output
(selectable between
NPN and PNP)
NPN (PNP) open collector x3ch, 30 VDC (Power supply voltage) or less,
residual voltage 1 V (2 V) or less, N.O./N.C. selectable Max. 50 mA/ch 1.
Response time
(judgement output)
1.96 to 4031.72 ms 2.
Edge check output
(selectable between
NPN and PNP)
NPN (PNP) open collector x1ch, 30 VDC (Power supply voltage) or less,
residual voltage 1 V (2 V) or less, N.O./N.C. selectable Max. 50 mA, 1.
response time 20 ms
Analog output
(selectable among ±5V,
1-5 V, 0-5 V, 4-20 mA)
  Voltage output Current output
Output range ±5 V (full scale 10 V) 4-20 mA (full scale 16 mA)
Output resistance 100 Ω -
Maximum load resistance - 350 Ω
Repetition accuracy ±1 mV ±1.5 μA
Display accuracy ±0.05 % of F.S. ±0.25 % of F.S.
Temperature characteristics ±0.005 % of F.S./ºC ±0.01% of F.S./ºC
Update cycle Same as sensor head sampling cycle
Response time Same as Response time (judgement output)
Time constant 3. 10 μs (90 % response) 30 μs (90 % response)
Input Gain input Input time: 20 ms or more, Response delay time: 120 ms or less
(Nonvolatile memory (EEPROM) 1.5 s or less)
Reset input Input time: 20 ms or more, Response delay time: 20 ms or less
Timing input Input time: 2 ms or more, Response delay time: 2 ms or less
Zero shift input Input time: 20 ms or more, Response delay time: 20 ms or less
Bank A input/
Bank B input
Input time: 20 ms or more, Response delay time: 20 ms or less
Laser emission
stop input
Input time: 2 ms or more, Response delay time: 2 ms or less
Environment resistance Ambient temperature -10 to +50ºC 14 to 122Fº (No freezing)
Ambient humidity Ambient humidity
Vibration resistance 10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours
Pollution degree 2
Material Main unit case/Front sheet: Polycarbonate, Key top: Polyacetal, Cable: PVC
Supplied item Main body x 1,
Instruction manual x 1 (only for main unit)
Main body x 1, Panel mounting bracket x 1,
Front protection cover x 1, Power supply and
input/output cable (2 m 0.08") x 1,
Expansion cable (50 mm 1.97") x 1
(only for expansion unit),
Instruction manual x 1 (only for main unit)
Weight (including supplied items) Approx. 150 g Approx. 140 g Approx. 170 g Approx. 165 g
1. When expansion units are added: Max. 20 mA/ch
2. For more details, refer to the User’s Manual.
3. Delay time that occurs from the analog output circuit after the judgment is output.
Communication unit (Common specifications)
Model DL-RB1A DL-RS1A
Appearance DL-RB1A DL-RS1A2.
2 Power supply voltage 20 to 30 VDC, including ripple, Ripple (P-P): 10% max. (Supplied via connected sensor amplifier)
Power consumption (including analog current output) 27 mA max. 25 mA max.
Number of connectable sensor amplifiers Up to 4 units (including main unit) 1.
Indicator Alarm indicator lamp (red),
Power indicator lamp (green)
Communication indicator lamp (green x 2),
Alarm indicator lamp (red),
Power indicator lamp (green)
Communication method - Full duplex
Synchronization method - Start-stop
Transmission code - ASCII
Baud rate - 2400/4800/9600/19200/38400 bps selectable (Factory-setting: 9600 bps)
Data bit length - 8 bits/7 bits selectable (Factory-setting: 8 bits)
Parity check - None/Even/Odd selectable (Factory-setting: None)
Stop bit length - 1 bit
Data delimiter - Data reception: automatically recognizes CR or CR+LF
Data transmission: Fixed to CR+LF
Environment resistance Ambient temperature -10 to +55ºC 14 to 131Fº (No freezing)
Ambient humidity 35 to 85%RH (No condensation)
Vibration resistance 10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours
Material Main unit case/Front sheet: Polycarbonate
Weight Approx. 46 g Approx. 53 g
Supplied item Instruction manual, End units x 2, Switch protection seal, Expansion connector cover
1. A single communication unit can retrieve data from up to 4 display units.
2. DL-RS1A units purchased before July 14, 2009 cannot be used.


For Full Details
Download the Product Catalog

Support and Services

Ask The Experts
Price Info
Free Trial Unit
Contact Us
Let the Keyence Experts answer your questions. Request price information on a product. Try out a measurement product free of charge. Feel free to contact us anytime.

New Topics

Large Target Measurement Guide Instantly Measure Multiple Areas with Easy Operation Dramatically Improve Workplace Practices General Catalog
Large Target Measurement GuideWhat Should You Do When Measuring a Large Workpiece? Measure Multiple Areas with EaseSimplify and Shorten the Time Spent on Dimensional Measurement Inductive Displacement Sensors GuideDownload Your Copy of Inductive Displacement Sensors General CatalogJust released get your copy today.

Other Measurement Topics

12 Page Advanced Measurement Technique Guide Comprehensive R&D Measurement Guide
Download These Illustrated Tips Now! Laser Displacement Sensor Specifications