IG Series
Multi-Purpose CCD Laser Micrometer |

|
Specifications 1
IG Series Multi-Purpose CCD Laser Micrometer
Best in Class Performance with the Specifications to Back it Up.
| Sensor heads |
| Model |
IG-010 |
IG-028 |
| Appearance |
 |
 |
| Operation principle |
CCD method |
| Light source |
|
Visible light semiconductor laser (Wavelength:660 nm) |
FDA (CDRH) Part 1040.10 |
Class 1 1. |
| IEC60825-1 |
Class 1 |
| Mounting distance |
0 to 1000 mm 39.37" |
0 to 1500 mm 59.06" |
| Measurement range |
10 mm 0.39" |
28 mm 1.10" |
| Sampling cycle |
980μs (When the number of times for averaging is set to [hsp]: 490μs) |
Minimum detectable object 2. |
High sensitivity mode |
ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94") |
| Standard mode |
ø0.2 mm ø0.007"
(Setting distance: 40 mm 1.57" or less),
ø0.5 mm ø0.02"
(Setting distance: 500 mm 19.68") |
ø0.2 mm ø0.007"
(Setting distance: 50mm 1.97" or less),
ø0.5 mm ø0.02"
(Setting distance: 500 mm 19.68") |
| Repeatability 3. |
5 μm 0.20 Mil
(Setting distance: 100 mm 3.94")
10 μm 0.39 Mil
(Setting distance: 500 mm 19.68")
80 μm 3.15 Mil
(Setting distance: 1000 mm 39.37") |
5 μm 0.20 Mil
(Setting distance: 100 mm 3.94")
10 μm 0.39 Mil
(Setting distance: 500 mm 19.68")
80 μm 3.15 Mil
(Setting distance: 1000 mm 39.37")
140 μm 5.51 Mil
(Setting distance: 1500 mm 59.06") |
| Linearity 4. |
±0.28 % of F.S. (±28 μm ±1.10 Mil) |
±0.1 % of F.S. (±28 μm ±1.10 Mil) |
| Temperature characteristics 5. |
±0.03 % of F.S./ºC (±3 μm ±0.12 Mil/ºC) |
±0.01 % of F.S./ºC (±3 μm ±0.12 Mil/ºC) |
| Operation indicator |
Transmitter |
Optical axis alignment indicator: Green LED Power indicator: Green LED |
| Receiver |
Optical axis alignment indicator: Green LED Position monitor:
Dual bar LED (Red, Green) |
| Environment resistance |
Enclosure rating |
IP67 |
Ambient temperature |
-10 to +45ºC 14 to 113Fº (No freezing) |
| Ambient humidity |
35 to 85% RH (No condensation) |
| Ambient light 6. |
Incandescent lamp: 5000 lux Sunlight: 5000 lux |
Vibration resistance |
10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours |
| Material |
Case |
Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part),
SUS304 (Metallic part) |
| Lens cover |
Glass |
| Cable |
PVC |
| Supplied item |
Transmitter x 1, Receiver x 1, Sensor head cables (2 m 0.08") x 2 |
| Weight (including supplied items) |
Approx. 380 g |
Approx. 500 g |
|
1. The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
2. When the measurement target object is measured at the center position of the setting distance.
When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm 0.003" or more can be detected (Setting distance: 500 mm 19.69").
3. When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds. (When the analog output is used, the margin of error of analog output is added.)
4. When the setting distance is 100 mm 3.94” and light is shielded at 50 mm 1.96" position from the receiver. Margin of error to the ideal line.
5. When the setting distance is 100 mm 3.94” and light is shielded by half at 50 mm 1.96” position from the receiver.
6. Excluding when the average number of times is set to [hsp]. |
| Display unit (amplifier) |
| Model |
IG-1000 |
IG-1050 |
IG-1500 |
IG-1550 |
| Appearance |
 |
 |
 |
 |
| Amplifier type |
DIN rail mount |
Panel mount |
| Main unit/Expansion unit |
Main unit |
Expansion unit |
Main unit |
Expansion unit |
| Analog output |
Yes |
No |
Yes |
No |
| Power supply voltage |
10-30 VDC, Ripple (P-P): 10% included, Class 2 |
Power consumption (including analog current output) |
Normal |
2700 mW or less (at 30 V: 90 mA or less) |
2880 mW or less (at 30 V: 96 mA or less) |
Power saving function (HALF) |
2300 mW (at 30 V: 77 mA or less) |
Power saving function (ALL) |
2200 mW (at 30 V: 74 mA or less) |
| Digital display method |
Dual 7-seg display Upper level: Red, 5 digits Lower level: Green, 5 digits |
Dual 7-seg display Upper level: Red/Green, 2 colors, 5 digits Lower level: Green, 5 digits |
| Display range |
-99.999 to +99.999, -99.99 to +99.99, -99.9 to +99.9, -99 to +99 (selectable) |
| Display resolution |
1 μm 0.04 Mil, 10 μm 0.39Mil, 100 μm 3.94 Mil, 1000 μm 39.37 Mil(selectable ) |
| Output |
Judgement output (selectable between NPN and PNP) |
NPN (PNP) open collector x3ch, 30 VDC (Power supply voltage) or less, residual voltage 1 V (2 V) or less, N.O./N.C. selectable Max. 50 mA/ch 1. |
Response time (judgement output) |
1.96 to 4031.72 ms 2. |
Edge check output (selectable between NPN and PNP) |
NPN (PNP) open collector x1ch, 30 VDC (Power supply voltage) or less, residual voltage 1 V (2 V) or less, N.O./N.C. selectable Max. 50 mA, 1. response time 20 ms |
Analog output (selectable among ±5V, 1-5 V, 0-5 V, 4-20 mA) |
| |
Voltage output |
Current output |
| Output range |
±5 V (full scale 10 V) |
4-20 mA (full scale 16 mA) |
| Output resistance |
100 Ω |
- |
| Maximum load resistance |
- |
350 Ω |
| Repetition accuracy |
±1 mV |
±1.5 μA |
| Display accuracy |
±0.05 % of F.S. |
±0.25 % of F.S. |
| Temperature characteristics |
±0.005 % of F.S./ºC |
±0.01% of F.S./ºC |
| Update cycle |
Same as sensor head sampling cycle |
| Response time |
Same as Response time (judgement output) |
| Time constant 3. |
10 μs (90 % response) |
30 μs (90 % response) |
|
| Input |
Gain input |
Input time: 20 ms or more, Response delay time: 120 ms or less (Nonvolatile memory (EEPROM) 1.5 s or less) |
| Reset input |
Input time: 20 ms or more, Response delay time: 20 ms or less |
| Timing input |
Input time: 2 ms or more, Response delay time: 2 ms or less |
| Zero shift input |
Input time: 20 ms or more, Response delay time: 20 ms or less |
Bank A input/ Bank B input |
Input time: 20 ms or more, Response delay time: 20 ms or less |
Laser emission stop input |
Input time: 2 ms or more, Response delay time: 2 ms or less |
| Environment resistance |
Ambient temperature |
-10 to +50ºC 14 to 122Fº (No freezing) |
| Ambient humidity |
Ambient humidity |
| Vibration resistance |
10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours |
| Pollution degree |
2 |
| Material |
Main unit case/Front sheet: Polycarbonate, Key top: Polyacetal, Cable: PVC |
| Supplied item |
Main body x 1, Instruction manual x 1 (only for main unit) |
Main body x 1, Panel mounting bracket x 1, Front protection cover x 1, Power supply and input/output cable (2 m 0.08") x 1,
Expansion cable (50 mm 1.97") x 1 (only for expansion unit), Instruction manual x 1 (only for main unit) |
| Weight (including supplied items) |
Approx. 150 g |
Approx. 140 g |
Approx. 170 g |
Approx. 165 g |
|
1. When expansion units are added: Max. 20 mA/ch
2. For more details, refer to the User’s Manual.
3. Delay time that occurs from the analog output circuit after the judgment is output. |
| Communication unit (Common specifications) |
| Model |
DL-RB1A |
DL-RS1A |
| Appearance |
 |
2. |
| 2 Power supply voltage |
20 to 30 VDC, including ripple, Ripple (P-P): 10% max. (Supplied via connected sensor amplifier) |
| Power consumption (including analog current output) |
27 mA max. |
25 mA max. |
| Number of connectable sensor amplifiers |
Up to 4 units (including main unit) 1. |
| Indicator |
Alarm indicator lamp (red), Power indicator lamp (green) |
Communication indicator lamp (green x 2), Alarm indicator lamp (red), Power indicator lamp (green) |
| Communication method |
- |
Full duplex |
| Synchronization method |
- |
Start-stop |
| Transmission code |
- |
ASCII |
| Baud rate |
- |
2400/4800/9600/19200/38400 bps selectable (Factory-setting: 9600 bps) |
| Data bit length |
- |
8 bits/7 bits selectable (Factory-setting: 8 bits) |
| Parity check |
- |
None/Even/Odd selectable (Factory-setting: None) |
| Stop bit length |
- |
1 bit |
| Data delimiter |
- |
Data reception: automatically recognizes CR or CR+LF Data transmission: Fixed to CR+LF |
| Environment resistance |
Ambient temperature |
-10 to +55ºC 14 to 131Fº (No freezing) |
| Ambient humidity |
35 to 85%RH (No condensation) |
| Vibration resistance |
10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours |
| Material |
Main unit case/Front sheet: Polycarbonate |
| Weight |
Approx. 46 g |
Approx. 53 g |
| Supplied item |
Instruction manual, End units x 2, Switch protection seal, Expansion connector cover |
|
1. A single communication unit can retrieve data from up to 4 display units.
2. DL-RS1A units purchased before July 14, 2009 cannot be used. |
For Full Details
Download the Product Catalog
Support and Services
New Topics
Other Measurement Topics
|
|