LJ-G 2D Laser Displacement Sensor Sensor Head Specifications
Best in Class Performance with the Specifications to Prove it
LJ-G series sensor head
Model
LJ-G015K
LJ-G015
LJ-G030
LJ-G080
LJ-G200
Type
Specular reflective
Diffuse reflective
Reference distance
15 mm 0.59"
30 mm 1.18"
80 mm 3.15"
200 mm 7.87"
Measuring
range
Z-axis (Height)
±2.3 mm ±0.09"
±2.6 mm 0.1"
±10 mm ±0.39"
±23 mm ±0.91"
±48 mm ±1.89"
X-axis (Width)
Near
6.5 mm 0.26"
20 mm 0.79"
25 mm 0.98"
51 mm 2.01"
Reference distance
7.0 mm 0.28"
22 mm 0.87"
32 mm 1.26"
62 mm 2.44"
Far
7.5 mm 0.30"
25 mm 1.98"
39 mm 1.54"
73 mm 2.87"
Red semiconductor laser
Light source
Wavelength
650 nm (Visible light)
Laser Class
Class II (FDA CDRH 21CFR PART1040.10)
Output
0.95 mW
Spot diameter (at reference distance)
Approx. 32 μm x 12 mm 1.26 Mil x 0.47"
Approx. 40 μm x 25 mm 1.57 Mil x 0.98"
Approx. 80 μm x 46 mm 3.15 Mil x 1.81"
Approx. 180 μm x 70 mm 7.09 Mil x 2.76"
Repeatability 1.
Z-axis (Height) 2.
0.2 μm 0.008 Mil
1 μm 0.04 Mil
1 μm 0.04 Mil
2 μm 0.08 Mil
X-axis (Width) 3.
2.5 μm 0.10 Mil
5 μm 0.20 Mil
10 μm 0.39 Mil
20 μm 0.78 Mil
Linearity Z-axis (Height) 2.
±0.1% of F.S.
Sampling frequency (Trigger pitch) 4.
3.8 ms
Temperature characteristics
0.02% of F.S./ºC
Environmental resistance
Enclosure rating
IP67 (IEC60529)
Ambient illumination 5.
Incandescent lamp or fluorescent lamp: 5,000 lux max..
Ambient temperature
0 to 50ºC (32 to 122ºF)
Relative humidity
35 to 85% (No condensation)
Vibration
10 to 55 Hz, multiple amplitude 1.5 mm 0.06", two hours in each direction of X, Y and Z
Material
Aluminum
Weight
Approx. 260 g
Approx. 290 g
Approx. 350 g
Approx. 480 g
1. The value obtained after 64 times Averaging at the reference distance.
2. The target is KEYENCE standard object. (White diffusing material). The value is the average of the widths in the Height mode.
3. The target is ø10 mm pin gauge. The value is the edge in the Position mode after 16 times of the Smoothing.
4. When the measuring range is the minimum in the initial setting.
5. The illumination on the receiver of the sensor head when targeting an illuminated white paper.