Best in Class Performance with the Specifications to Prove it
LK-G Series Sensor Head Variations LK-G Series Laser Displacement Sensor Head Specifications
Model
LK-G10/G15
LK-G32/ G37
Mounting mode
-
Diffused reflection
Specular reflection
Reference distance
0.39" 10 mm
1.18" 30 mm
0.93" 23.5 mm
Measuring range 1.
±0.04" ±1 mm
±0.2" ±5 mm
±0.18" ±4.5 mm
Red semiconductor laser
Light source
Wavelength
650 nm (visible light)
650 nm (visible light)
Laser Class
Class II (FDA CDRH 21CFR PART1040.10)
Class II (FDA CDRH 21CFR PART1040.10)
Output
0.3 mW
0.95 mW
Spot diameter (at reference distance)
Approx. 0.79 x 20 Mil 20 x 500 μm (G15),
Approx. ø0.79 Mil ø20 μm (G10)
Approx. 1.18 x 33.46 Mil 30 x 850 μm (G37),
Approx. ø1.18 Mil ø30 μm (G32)
Linearity 2.
±0.03% of F.S. (F.S.=±0.04" ±1 mm)
±0.05% of F.S. (F.S.= ±0.2" ±5 mm)
Repeatability 3.
0.0008 Mil (0.0004 Mil) 0.02 μm (0.01 μm)
0.002 Mil 0.05 μm
Sampling frequency
20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display
Near the center of the measurement: Green lights
Within the measurement area: Orange lights Outside the measurement area: Orange flashing
Temperature characteristics
0.01% of F.S./ºC (F.S.=±0.04" ±1 mm)
0.01% of F.S./ ºC (F.S.= ±0.2" ±5 mm)
Environmental
resistance
Enclosure rating
IP67 (IEC60529)
Ambient luminance
Incandescent lamp or fluorescent lamp: 10,000 lux max.
Ambient temperature
0 to +50ºC (32 to 122ºF), No condensation
Relative humidity
35 to 85%, No condensation
Resistance to vibrations
10 to 55 Hz, multiple amplitude 0.06" 1.5 mm; two hours in each direction of X, Y, and Z
Material
Aluminum die-cast
Weight (including the cable)
Approx. 190 g
Approx. 280 g
1. The range is obtained by measuring KEYENCE’s standard target (ceramic).
LK-G10/G15: When the sampling rate is 20 μs, the range becomes +0.37 (FAR side) to -1 mm (NEAR side).
LK-G32/G37: When the sampling rate is 20 μs, the range becomes +1.8 (FAR side) to -5 mm (NEAR side) for diffuse reflection, and +1.6 mm (FAR side) to -4.5 mm (NEAR side) for specular reflection.
2. The range is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
3. The range is obtained by measuring KEYENCE’s standard (SUS) with 4096 times of averaging at the reference distance. The range in parenthesis is the typical linearity obtained by measuring the target with 16384.
Model
LK-G82/G87
LK-G152/G157
Mounting mode
Diffused reflection
Specular reflection
Diffused reflection
Specular reflection
Reference distance
3.15" 80 mm
2.96" 75.2 mm
5.91" 150 mm
5.81" 147.5 mm
Measuring range 1.
±0.59" ±15 mm
±0.55" ±14 mm
±1.57" ±40 mm
±1.54" ±39 mm
Red semiconductor laser
Light source
Wavelength
650 nm (visible light)
Laser Class
Class II (FDA CDRH 21CFR PART1040.10)
Output
0.95 mW
Spot diameter (at reference distance)
Approx. 2.76 x 43.3 Mil 70 x 1100 μm (G87),
Approx. ø2.76 Mil ø70 μm (G82)
Approx. 4.72 x 66.9 Mil 120 x 1700 μm (G157),
Approx. ø4.72 Mil ø120 μm (G152)
Linearity 2.
±0.05% of F.S. (F.S.= ±0.59" ±15 mm)
±0.05% of F.S. (F.S.= ±1.57" ±40 mm)
Repeatability 3.
0.008 Mil 0.2 μm
0.02 Mil 0.5 μm
Sampling frequency
20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display
Near the center of the measurement: Green lights
Within the measurement area: Orange lights Outside the measurement area: Orange flashing
Temperature characteristics
0.01% of F.S./ºC (F.S.= ±0.59" ±15 mm)
0.01% of F.S./ºC (F.S.= ±1.57" ±40 mm)
Environmental
resistance
Enclosure rating
IP67 (IEC60529)
Ambient luminance
Incandescent lamp or fluorescent lamp: 10,000 lux max.
Incandescent lamp or fluorescent lamp: 5000 lux max.
Ambient temperature
0 to +50ºC (32 to 122ºF), No condensation
Relative humidity
35 to 85%, No condensation
Resistance to vibrations
10 to 55 Hz, multiple amplitude 0.06" 1.5 mm; two hours in each direction of X, Y, and Z
Material
Aluminum die-cast
Weight (including the cable)
Approx. 380 g
Approx. 290 g
1. The range is obtained by measuring KEYENCE’s standard target (ceramic).
LK-G82/G87: When the sampling rate is 20 μs, the range becomes -9 (NEAR side) to -15 mm(NEAR side) for diffuse reflection, and -8.7 (NEAR side) to -14 mm (NEAR side) for specular reflection.
LK-G152/G157: When the sampling rate is 20 μs, the range becomes -22 (NEAR side) to -40 mm(NEAR side) for diffuse reflection, and -22 (NEAR side) to -39 mm (NEAR side) for specular reflection.
2. The range is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
3. The range is obtained by measuring KEYENCE’s standard (SUS) with 4096 times of averaging at the reference distance. The range in parenthesis is the typical linearity obtained by measuring the target with 16384.
LK-G400/G500 Series Sensor Head Specifications
Model
LK-G407/LK-G402
LK-G507/LK-G502
Mounting mode
Diffused reflection
Specular reflection
Diffused reflection
Specular reflection
Reference distance
15.75" 400 mm
15.67" 398 mm
19.69" 500 mm
19.59" 497.5 mm
Measuring range1.
3.94" ±100 mm
3.90" ±99 mm
-9.84" to 19.69"
-250 to +500 mm
-9.80" to 19.61"
-249 to +498 mm
Red semiconductor laser
Light source
Wavelength
650 nm (visible light)
Laser Class
Class II (FDA CDRH 21CFR PART1040.10)
Output
0.95 mW
Spot diameter (at reference distance)
Approx. 11.42 x 326.8 Mil
290 x 8300 μm (G407)
Approx. ø11.42 Mil ø290 μm (G402)
Approx. 11.81 x 374 Mil
300 x 9500 μm (G507)
Approx. ø11.8 Mil ø300 μm (G502)
Linearity 2.
±0.05% of F.S.(F.S.= ±3.94" ±100 mm)
±0.05% of F.S. (±9.84 Mil ±250 μm) 4. 5. -9.84" to +9.84" -250 mm to +250 mm
<high-accuracy range>
±0.02% of F.S. (±3.9 Mil ±100 μm) -9.84" to -1.97"-250 mm to -50 mm
<long range>
±0.1% of F.S. (±19.5 Mil ±500 μm) -9.84" to -19.69"-250 mm to +500 mm
(F.S. = ±9.84"±250 mm)
Repeatability 3.
0.08 Mil 2 μm
Sampling frequency
20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display
Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing
Temperature characteristics
0.01% of F.S./ºC (F.S.= ±3.94" ±100 mm)
0.01% of F.S./ºC (F.S.= ±9.84" ±250 mm)
Enclosure rating
IP67 (IEC60529)
Ambient light
Incandescent lamp or fluorescent lamp: 5000 lux max.
Ambient temperature
Relative humidity
Incandescent lamp or fluorescent lamp: 5000 lux max.
0 to +50ºC (32 to 122ºF), No condensation
35 to 85%, No condensation
Vibrations
10 to 55 Hz, multiple amplitude 0.06" 1.5 mm; two hours in each direction of X, Y, and Z
Material
Aluminum die-cast
Weight (including the cable)
Approx. 380 g
1.The range is obtained by measuring KEYENCE's standard target (ceramic).
(LK-G407/LK-G402)
When the sampling rate is 20 μs, the range becomes -2.76" (-70 mm) (NEAR side) to -3.94" (-100 mm) (NEAR side) for diffuse reflection.
When the sampling rate is 20 μs, the range becomes -2.76" (-70 mm) (NEAR side) to -3.90" (-99 mm) (NEAR side) for specular reflection.
(LK-G507/LK-G502)
When the sampling rate is 20 μs, the range becomes -9.06" (-230 mm) (NEAR side) to -9.84" (-250 mm) (NEAR side) for diffuse reflection.
When the sampling rate is 20 μs, the range becomes -9.06" (-230 mm) (NEAR side) to -9.80" (-249 mm) (NEAR side) for specular reflection.
When the sampling rate is 50 μs, the range becomes -4.92" (-125 mm) (NEAR side) to -9.84" (-250 mm) (NEAR side) for diffuse reflection.
When the sampling rate is 50 μs, the range becomes -4.92" (-125 mm) (NEAR side) to -9.80" (-249 mm) (NEAR side) for specular reflection.
2. The range is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
3. The range is obtained by measuring KEYENCE’s standard (SUS) with 4096 times of averaging at the reference distance.
4. All are calculated at F.S. = ±9.84" (±250 mm).
5. “High accuracy range” and “long range” refer to the linearity when those ranges are used.