Products
Assembly Technology Expo

General Catalog

Want to learn how to use our products? - go to Application Finder Page

Explore theLatest Measurement System? - go to Product Finder Page

Laser Displacement Sensors from KEYENCE

LK-G Series

Laser Displacement Sensor
Print Page
 
Select a Page Below:
BackNext
Specifications 1

Best in Class Performance with the Specifications to Prove it



LK-G Series Sensor Head Variations
LK-G Series Sensor Head Variations
LK-G Series Laser Displacement Sensor Head Specifications
Model LK-G10/G15 LK-G32/ G37
Mounting mode   Diffused reflection Specular reflection
Reference distance 0.39" 10 mm 1.18" 30 mm 0.93" 23.5 mm
Measuring range (1) ±0.04" ±1 mm ±0.2" ±5 mm ±0.18" ±4.5 mm
Light source Type Red semiconductor laser
Wavelength 650 nm (visible light), Class II (FDA) 650 nm (visible light), Class II (FDA)
Output 0.3 mW max. 0.95 mW max.
Spot diameter (at reference distance) Approx. 0.78 x 20 Mil
20 x 500 μm (G15),
Approx. ø0.78 Mil ø20 μm (G10)
Approx. 1.17 x 33.15 Mil
30 x 850 μm (G37),
Approx. ø1.17 Mil ø30 μm (G32)
Linearity (2) ±0.03% of F.S. (F.S.=±0.04" ±1 mm) ±0.05% of F.S. (F.S.= ±0.2" ±5 mm)
Resolution (3) 0.0008 Mil (0.0004 Mil) 0.02 μm
(0.01 μm)
0.002 Mil 0.05 μm (4)
Sampling frequency 20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display Near the center of the measurement: Green lights
Within the measurement area: Orange lights Outside the measurement area: Orange flashing
Temperature characteristics 0.01% of F.S./ºC (F.S.=±0.04" ±1 mm) 0.01% of F.S./ ºC (F.S.= ±0.2" ±5 mm)
Environmental
resistance
Protective construction IP-67 (IEC60529)
Ambient luminance Incandescent lamp or fluorescent lamp: 10,000 lux max.
Ambient temperature 0 to +50ºC (32 to 122ºF), No condensation
Relative humidity 35 to 85%, No condensation
Resistance to vibrations 10 to 55 Hz, multiple amplitude 0.06" 1.5 mm;
two hours in each direction of X, Y, and Z
Material Aluminum die-cast
Weight (including the cable) Approx. 190 g Approx. 280 g

Model LK-G82/G87 LK-G152/G157
Mounting mode Diffused reflection Specular reflection Diffused reflection Specular reflection
Reference distance 3.15" 80 mm 2.96" 75.2 mm 5.91" 150 mm 5.81" 147.5 mm
Measuring range (1) ±0.59" ±15 mm ±0.55" ±14 mm ±1.57" ±40 mm ±1.54" ±39 mm
Light source Type Red semiconductor laser
Wavelength 650 nm (visible light), Class II (FDA)
Output 0.95 mW max.
Spot diameter (at reference distance) Approx.2.76" x 43.3 Mil
70 x 1100 μm (G87),
Approx. ø2.76Mil ø70μm (G82)
Approx. 4.68 x 66.3 Mil
120 x 1700 μm (G157),
Approx. ø4.68 Mil ø120 μm (G152)
Linearity (2) ±0.05% of F.S. (F.S.= ±0.59" ±15 mm) ±0.05% of F.S. (F.S.= ±1.57" ±40 mm)
Resolution (3) 0.008 Mil 0.2 μm (4) 0.02 Mil 0.5 μm (4)
Sampling frequency 20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display Near the center of the measurement: Green lights
Within the measurement area: Orange lights Outside the measurement area: Orange flashing
Temperature characteristics 0.01% of F.S./ºC (F.S.=±0.59" ±15 mm) 0.01% of F.S./ ºC (F.S.= ±1.57" ±40 mm)
Environmental
resistance
Protective construction IP-67 (IEC60529)
Ambient luminance Incandescent lamp or fluorescent lamp: 10,000 lux max.
Ambient temperature 0 to +50ºC (32 to 122ºF), No condensation
Relative humidity 35 to 85%, No condensation
Resistance to vibrations 10 to 55 Hz, multiple amplitude 0.06" 1.5 mm;
two hours in each direction of X, Y, and Z
Material Aluminum die-cast
Weight (including the cable) Approx. 280 g Approx. 290 g
1. The value is obtained by measuring KEYENCE’s standard target (ceramic).
LK-G10/G15: When the sampling rate is 20μs, the value becomes +0.37(FAR side) to -1mm (NEAR side).
LK-G32/G37: When the sampling rate is 20μs, the value becomes +1.8(FAR side) to -5mm (NEAR side) for diffuse reflection, and +1.6mm(NEAR side) to -4.5mm (NEAR side) for specular reflection.
LK-G82/G87: When the sampling rate is 20μs, the value becomes -9(NEAR side) to -15mm(NEAR side) for diffuse reflection, and -8.7(NEAR side) to -14mm(NEAR side) for specular reflection.
LK-G152/G157: When the sampling rate is 20μs, the value becomes -22(NEAR side) to -40mm(NEAR side) for diffuse reflection, and -22(NEAR side) to -39mm(NEAR side) for specular reflection.
2. The value is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
3. The value is obtained by measuring KEYENCE's standard(SUS) with 4096 times of averaging at the reference distance. The value in parenthesis is the typical resolution obtained by measuring the target with 16384.
4. This product is subject to export controls of strategic materials, etc., under the regulations of the Foreign Exchange and Foreign Trade Control Law. To take this product out of Japan, you must submit a formal application for an export license to the Japanese government. The following products are not subject to export controls.

Warning
The LK-G Series coforms to FDA and IEC standards as follows:
For Full Details
Download the Product Catalog

Support and Services

Ask The Experts
Price Info
Free Trial Unit
Contact Us
Let the Keyence Experts answer your questions. Request price information on a product. Try out a measurement product free of charge. Feel free to contact us anytime.

New Topics

Download Automatic Shape Analysis Program   The Original Standard in
Non-contact Dimensional Measurement
  KAIZEN Quality Improvement Guides   General Catalog
Download Automatic Shape Analysis Program Excel Spreadsheet Offers Instant Solutions The Original Standard in Non-contact Dimensional MeasurementHigh Performance Achieved by Green LED KAIZEN Quality Improvement Guides2D Laser Displacement Sensor General Catalog Just released get your copy today.

Other Measurement Topics

Answers to Basic Questions about Non-contact Measurement Quality Management with Optical Micrometers