LK-G Series Sensor Head Variations
LK-G Series Sensor Head Variations
LK-G Series Laser Displacement Sensor Head Specifications
Model LK-G10/G15 LK-G32/ G37
Mounting mode   Diffused reflection Specular reflection
Reference distance 0.39" 10 mm 1.18" 30 mm 0.93" 23.5 mm
Measuring range (1) ±0.04" ±1 mm ±0.2" ±5 mm ±0.18" ±4.5 mm
Light source Type Red semiconductor laser
Wavelength 650 nm (visible light), Class II (FDA) 650 nm (visible light), Class II (FDA)
Output 0.3 mW max. 0.95 mW max.
Spot diameter (at reference distance) Approx. 0.78 x 20 Mil
20 x 500 μm (G15),
Approx. ø0.78 Mil ø20 μm (G10)
Approx. 1.17 x 33.15 Mil
30 x 850 μm (G37),
Approx. ø1.17 Mil ø30 μm (G32)
Linearity (2) ±0.03% of F.S. (F.S.=±0.04" ±1 mm) ±0.05% of F.S. (F.S.= ±0.2" ±5 mm)
Resolution (3) 0.0008 Mil (0.0004 Mil) 0.02 μm
(0.01 μm)
0.002 Mil 0.05 μm (4)
Sampling frequency 20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display Near the center of the measurement: Green lights
Within the measurement area: Orange lights Outside the measurement area: Orange flashing
Temperature characteristics 0.01% of F.S./ºC (F.S.=±0.04" ±1 mm) 0.01% of F.S./ ºC (F.S.= ±0.2" ±5 mm)
Environmental
resistance
Protective construction IP-67 (IEC60529)
Ambient luminance Incandescent lamp or fluorescent lamp: 10,000 lux max.
Ambient temperature 0 to +50ºC (32 to 122ºF), No condensation
Relative humidity 35 to 85%, No condensation
Resistance to vibrations 10 to 55 Hz, multiple amplitude 0.06" 1.5 mm;
two hours in each direction of X, Y, and Z
Material Aluminum die-cast
Weight (including the cable) Approx. 190 g Approx. 280 g

Model LK-G82/G87 LK-G152/G157
Mounting mode Diffused reflection Specular reflection Diffused reflection Specular reflection
Reference distance 3.15" 80 mm 2.96" 75.2 mm 5.91" 150 mm 5.81" 147.5 mm
Measuring range (1) ±0.59" ±15 mm ±0.55" ±14 mm ±1.57" ±40 mm ±1.54" ±39 mm
Light source Type Red semiconductor laser
Wavelength 650 nm (visible light), Class II (FDA)
Output 0.95 mW max.
Spot diameter (at reference distance) Approx.2.76" x 43.3 Mil
70 x 1100 μm (G87),
Approx. ø2.76Mil ø70μm (G82)
Approx. 4.68 x 66.3 Mil
120 x 1700 μm (G157),
Approx. ø4.68 Mil ø120 μm (G152)
Linearity (2) ±0.05% of F.S. (F.S.= ±0.59" ±15 mm) ±0.05% of F.S. (F.S.= ±1.57" ±40 mm)
Resolution (3) 0.008 Mil 0.2 μm (4) 0.02 Mil 0.5 μm (4)
Sampling frequency 20/50/100/200/500/1000 μs (Selectable from 6 levels)
LED display Near the center of the measurement: Green lights
Within the measurement area: Orange lights Outside the measurement area: Orange flashing
Temperature characteristics 0.01% of F.S./ºC (F.S.=±0.59" ±15 mm) 0.01% of F.S./ ºC (F.S.= ±1.57" ±40 mm)
Environmental
resistance
Protective construction IP-67 (IEC60529)
Ambient luminance Incandescent lamp or fluorescent lamp: 10,000 lux max.
Ambient temperature 0 to +50ºC (32 to 122ºF), No condensation
Relative humidity 35 to 85%, No condensation
Resistance to vibrations 10 to 55 Hz, multiple amplitude 0.06" 1.5 mm;
two hours in each direction of X, Y, and Z
Material Aluminum die-cast
Weight (including the cable) Approx. 380 g Approx. 290 g
1. The value is obtained by measuring KEYENCE’s standard target (ceramic).
LK-G10/G15: When the sampling rate is 20μs, the value becomes +0.37(FAR side) to -1mm (NEAR side).
LK-G32/G37: When the sampling rate is 20μs, the value becomes +1.8(FAR side) to -5mm (NEAR side) for diffuse reflection, and +1.6mm(NEAR side) to -4.5mm (NEAR side) for specular reflection.
LK-G82/G87: When the sampling rate is 20μs, the value becomes -9(NEAR side) to -15mm(NEAR side) for diffuse reflection, and -8.7(NEAR side) to -14mm(NEAR side) for specular reflection.
LK-G152/G157: When the sampling rate is 20μs, the value becomes -22(NEAR side) to -40mm(NEAR side) for diffuse reflection, and -22(NEAR side) to -39mm(NEAR side) for specular reflection.
2. The value is obtained by measuring KEYENCE’s standard target (ceramic) with the Standard mode.
3. The value is obtained by measuring KEYENCE's standard(SUS) with 4096 times of averaging at the reference distance. The value in parenthesis is the typical resolution obtained by measuring the target with 16384.
4. This product is subject to export controls of strategic materials, etc., under the regulations of the Foreign Exchange and Foreign Trade Control Law. To take this product out of Japan, you must submit a formal application for an export license to the Japanese government. The following products are not subject to export controls.

Warning
The LK-G Series coforms to FDA and IEC standards as follows:

LK-G Series Laser Displacement Sensor Controller Specifications
Model All-in-one model LK-G3001V/LK-G3001PV
Separate model (1) LK-G3001V/GD500 | LK-3001P/GD500
Display Head compatibility All LK-G sensor heads are compatible
Number of connectable sensors maximum of 2 units
Minimum display unit 0.0004 Mil 0.01 µm
Display range ±9999.99 mm to ±9999.99 μm ±9999.99" ±99.9999Mil
(Selectable from six levels)
Refresh rate 10 times/sec
Terminal block Analog voltage output ±10 V x 2 outputs, output impedance: 100 Ω
Analog current output 4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω
Timing input (3) For OUT1, non-voltage input
Reset input (3)
Auto-zero input (3)
Laser remote interlock input (3) Non-voltage input
Comparator output (2) For OUT1, NPN open-collector output
Alarm output (2) For OUT1, NPN open-collector output (N.C.)
Expansion connector Timing input (3) For OUT2, non-voltage input
Reset input (3)
Auto-zero input (3)
Program switching input (3) Non-voltage input x 3 inputs
Laser-Off input (3) For Head A/Head B, non-voltage input
Comparator output (2) For OUT2, NPN open-collector output
Alarm output (2) For OUT2, NPN open-collector output (N.C.)
Binary Binary output (2) Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output
Strobe output (2) NPN open-collector output
Binary selector output (2) NPN open-collector output
Binary selector input (3) Non-voltage input
RS-232C interface Measured data output and control input/output
(Maximum baud rate: 115200 bit/s, selectable)
USB interface In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)
Major functions 2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO, Sampling frequency setting, Mutual
interference prevention, Data storage, 8-program memory, ECO mode, ABLE setting, Target setting, ABLE tuning, Selection of measurement
surface of transparent target, Statistics processing, Connection of setting support software, Selectable head-mounting, etc.
Power supply voltage 24 VDC± 10%, Ripple: 10% (P to P) or less
Current consumption 500 mA or less with 1 head/600 mA or less with 2 heads
Ambient temperature 0 to +50ºC (32 to 122ºF), No condensatio
Relative humidity 35 to 85%, No condensation
Weight Approx. 480 g (LK-G3001V), Approx. 370 g (LK-G3001), Approx. 60 g (LK-GD500)
1. LK-G3001 can be operated singly. The measured value display and setting modifications can be performed on the display panel (LK-GD500) or via the setting support software (LK-H1W).
2. The rating of the NPN open-collector: 50 mA max (40V max), residual voltage of 0.5 V max
3. The rating of non-voltage input: 1 V or less ON voltage, 0.6 mA or less OFF current

For Full Details
Download the Product Catalog

Support and Services

Ask The Experts
Price Info
Free Trial Unit
Contact Us
Let the Keyence Experts answer your questions. Request price information on a product. Try out a measurement product free of charge. Feel free to contact us anytime.

New Topics

KAIZEN Quality Improvement   Excel Simple Solution Series   Automatically Calculate Planes and Inclinations   General Catalog
KAIZEN Quality ImprovementQuality Control Success Stories Excel Simple Solution SeriesMacro Automatically Calculates Standard Deviation Automatically Calculate Planes and InclinationsEXCEL worksheet PPI Calculation Macro General Catalog Just released get your copy today.

Other Measurement Topics

Download Automatic Shape Analysis Program The Original Standard in Non-contact Dimensional Measurement
KAIZEN Quality Improvement Guides Answers to Basic Questions about Non-contact Measurement